Cornbelt Power
Cooperative
2570 Nevada Avenue
Humboldt, Iowa 50548
WEDNESDAY, MAY
23rd at 10 AM
Inspection: Tuesday, May 22nd from 9 AM
to 3PM
Power Plant Equipment, Boilers, Turbines,
Pumps, Motors, Switchgear, Transformers, Coal Handling Equipment
(as is where is)
As part of our Decommissioning and
Demolition efforts we now have available for a very short time a
complete 42 MW Steam Power Plant. This coal-fired power plant
consists of four 60-cycle units including two 7.5 MW (ACG), one
11.5 MW (ACG), and one 15 MW (HCG) Elliott condensing steam
turbines. The station has been out of service since 1985 for Units
1 & 2, and since 1991 for Units 3 & 4. These coal-fired
units were well maintained and are located in an enclosed
structure. The units include, two 90,000 lbs / hr. stoker-type
boilers (Units 1 & 2) , Unit 3 boiler is a 125,000 lbs. / hr
stoker-type unit and Unit 4 boiler is a 165,000 lbs. / hr.
pulverized coal type with electrostatic precipitator. Coal
conveyor systems, crushers, transformers, auxiliary systems, and
controls are also available.
For more information, visit our web site
at www.marcor.com or call for
a free brochure 1-(800)-248-0571 | 1-(610)-269-3250 or contact
myself or Greg Hayes (see contact info at bottom).
Click on the following to view pictures
as well as additional holdings:
Christopher D. Hayes | Gregory J. Hayes
Marcor Remediation Inc. glowjax@netcarrier.com
| hayesg@marcor.com | www.marcor.com Phones 215-541-1608 | 610-269-3250 Ext. 4131 | 610-269-3393 |
800-248-0571
Fax 610-269-3393 | Cell 610-636-8077
Marcor Remediation Inc.
Trestle Bridge Business Center
540 Trestle Place
Downingtown, PA 19335
010504
Makita Generators New Model: G-5500 R
Type:
5500 watts or 5.5 KW
Model: G-5500 R
Max Output: 5500- 45.8A
Running speed: 3,600 rpm
Hertz: 60
DC Voltage: 12V. 8.3 amps
Engine Type: Robin EY40D
Displacement: 388CC
Horsepower: 10 hp
Fuel tank Capacity: 4.09Gal/15.5 liters
Fuel: Gasoline
Noise Level: 74 DB
Starter: Recoil
Weight: 170 Pounds
Warranty: One Year from Mfg.
1.1 MW Power Generation System
with Waste Heat Recovery - $180,000.00
Specifications:
Three (3) Cat G398NA (serial numbers 73B551, 550, 549) with hours
since new of:
96,829 hours (4,500 hours
since overhaul)
105,789 hours (16,000 hours
since overhaul)
107,002 hours (7,000 hours
since overhaul).
Three (3) Columbia Electric MFG
Co. Generators (480 Volt, 3 Phase) with voltage regulators, floor
standing manually paralleling switchgear and Alcad batteries.
The Central Switchgear has the following features for each
Generator:
Manual circuit breaker
KW Meter selectable to read
leg 1,2 or 3
Amp Meter selectable to read
leg 1,2, or 3
The Central Switchgear has a
Central Control Panel with status lights and meters including
meters to measure VAC, KW, HZ and AMPS of individual phases of
each unit or total system.
The Waste Heat Recovery System includes three (3) individual
“Vapor Phase” heat exchangers that converts engine heat to
steam (20 PSI, 275 degrees F).
System cooling is provided by a central air / water heat exchanger
combined with water / oil heat exchangers on each engine combined
with the waste heat recovery system.
Approximately $10,000 worth of new or rebuilt spare parts such as
governor actuators, magnetos, oil pumps, bearings, carburetor
parts, and miscellaneous exhaust heat recovery equipment.
Manuals, Specifications and Operation and Repair Records are
included.
Seller is
interested in a QUICK DEAL and will negotiate on the selling
price. These units can be yours at a bargain basement price. In
addition we also have available 2 NEW GE Frame 9's.
Please e-mail me direct for full SCOPE of SUPPLY to: james@k-net.co.th
5.7 Mw Wood burning Plant
in full Operating Condition
As part of our Decommissioning and
Demolition efforts we now have available a complete 5.7 Mw Wood
burning Plant in full Operating Condition. The 5.7 Mw steam power
plant is a California licensed facility with options for extended
leasing to meet re-powering requirements. The well maintained,
60-cycle unit (located in an enclosed structure) includes one 5.7
MW (tewac) condensing steam turbine, boiler (50,00 lbs./hr. Steam
capacity stoker type units), fuel conveyor systems, separator,
baghouse, stack, condenser, condensate pumps, and boiler feed
pumps. Transformers, auxiliary systems, and controls are also
available.
If you have an interest in this surplus
equipment, please get back to me by the first week in March or
sooner. For equipment photos and additional
Updates are made on a regular basis so please bookmark.
010305
Request for Proposals for Two Small Hydroelectric Sites
Georgetown Divide Public Utility
District Board of Directors is requesting proposals to restore and
reoperate two small hydroelectric sites within the District's
water conveyance system. Privately owned turbine-generator units
were previously operated at these sites from 1983 thru 1998, and
were removed by the owner. GDPUD proposes to resume energy
production at the sites and is seeking business proposals to
restore the facilities. 1) Tunnel Hill 600 kw, 2,100,000 kwh, and
2) Buckeye 396 kw, 1,500,000 kwh.
To obtain a detailed project description and a set of guidelines
for the proposal preparation, please contact Marie Davis at (530)
333-4356. Proposals are requested on or before March 7, 2001.
010223
Universal
Compression Centrifugal Natural Gas Compressor
Two skidded units each with
one Atlas Copco Model TP 10/10, two stage centrifugal gas
compressors driven by a Toshiba 3500 HP motor. Includes BASCO
cooler, one Allen Bradley SLC5/05 PLC and standard UCI Pressure
Vessels.
Three NEW KCI
natural gas compressors designed to support LM6000 gas turbines.
2250HP motor driven skid mounted compressor. Cooling system
includes one aftercooler(120F discharge) and two oil coolers.
Includes one mesh pad design suction scrubber, pulsation bottles
located at suction and discharge of compressor cylinders, high
performance discharge coalescer designed to remove aerosols and
particulates, discharge accumulator, piping and valves to allow
automatic bypass of fuel.
Power Barge
of capacity 2x200 kW (60Hz GE), commissioned in 1998 available for
immediate sale at low price.
Interested party kindly
contact:
Peter Wong | apaerospace@yahoo.com
| fax: 65-2417029 or 65-2140312
010223
3 New Units, GE Frame 6's. ZERO Hours Use
NOTE. Seller is interested in a QUICK DEAL
and will negotiate on the selling price. These units can be yours
at a bargain basement price. In addition we also have available 2
NEW GE Frame 9's.
Please e-mail me direct for full SCOPE of SUPPLY to: james@k-net.co.th
We are a Bangkok based company. We have a
large inventory of New and Used GE generator sets.Units available
for immediate delivery FOB or Ex Works. e-mail to: james@k-net.co.th
for full list and scope of supply. If you are a Broker responding,
please only do so if you have a genuine Prospect and or Customer
who can complete a purchase with NO delays
2 NEW Ge Frame 9's for sale. Both units
are still in manufacturers packing crates. The units have zero
hours use. available now for immediate delivery. Interested
parties will need to furnish us with letter of INTEREST (on there
Letterhead) on receipt we will provide Scope of Supply. All
Brokers please only respond to this add if you have a genuine
Buyer and or Prospect
Amature connection: Star with neutral/Zig-Zag
Power factor: 0.8
Insulation: Class H
Sound level dB(A): 60
Starting system: Electric
Design: 4-cycle, Water cooled ,direct injection
No.cylinders: 6
Fuel Tank Capacity(gal): 126
Fuel Consumption: 4.4gph
L× W × H(ft): 9.51 × 3.61 × 5.91
Single phase120V 125 A
Single phase 277V 54.2 A
Three phase 208V 134 A
Three phase 480V 67 A
100%load 26
15kw/kva
single phase and 15kw or 18.8kva three phase.
Was hooked up to natural gas, can run on gasoline also; installed
in late 1990; Options: 8105 C1 F37 H1 H49 H335; 480 volt, 60 amp,
1/3 phase, 60hz; panel auto switches from utility power to gen set
power; in storage at Honeywell facility.
15.5 MW net
output natural gas fired power plant comprised of three Wartsila
engines and Dresser Rand steam turbine.
Qty 3 Wartsila, Model 18V32GD Engines
RPM 720
Rated Output 5.432 MW
Main Fuel Natural Gas
Pilot Fuel Distillate Oil
18 cylinder engine
Woodward 501 Control
Alstom Generator
Output voltage 4160V
Engines are equipped with ABB turbochargers
525 KW,
12,870 hours,
VGF Lean combustion engine
Turbocharged and Intercooled,
V12-Cylinders, H.P. 800,
Electron ignition
1,800 RPMs,
5.6 MMBTU/hr at full load,
date placed into service 11-98,
model # L36GLD,
serial # is C-12525-1 ,
located in Minneapolis
http://www.tradeout.com/product/details.asp?AuID=193951&ref=pmb2401
Pennsysvania,15/20/25 KVA Transformer
3-Phase, 60 HZ, Load Tap Changing Transformer, Primary V 67000
Delta,
Secondary V 12470Y/7200, Imp 7.4%
In good working condition
New GE Prolec Transformer with factory
warranty. 45/60/75 MVA OA/FA/FA Continuous rating at 55C rise.
138KV Y / 13.8KV Delta
No Load HV tap changer +/- 2.5%
BIL Ratings
HV Bushing 650
HV Winding 650
LV & HO Bushing 110
LV & HO Winding 110
Shipping weight without oil 110,103 Lbs
Total weight with oil 179,580 lbs
2.5 MW power
Low noise levels
Gas fuel configuration
Water injection capable
Digital control system
Aftermarket support
Function control system.
Includes:
Solar Centaur GS 4000 gas turbine Generator at 4160 VAC
TDI start system
Gas fuel system
Reduction gearbox
Lube oil cooling system
Air inlet filteration system
Digital control system
Part number 1801K222G01 is the same as the
bushing listed here , 1801K095G03, except that the bushing listed
here includes mounting hardware and gaskets. This bushing has a 2
hole blade at the LV termination and a single hole in the blade
for connection inside the transformer.
Gasket 2.75 inches
3 hole ring clamp 2.75 inches ID
.5 inch flange
.375 inch hole size on blade
.375 inch stud
Model # CX6-753-425E Serial # 355-630-3807-578 Stock# 99305
Rated Capacity: 6,000 Lb.
Capacity with Load Center 24 from Face of Fork and 21 Above Forks:
4150 Lb.
Maximum Lift Height: 187 (15' 5)
Free Lift: 64 1/2
Fork Width: 5
Fork Length: 41
Maximum Distance Across Forks: 36
Overall Height to Top of Mast: 82
Overall Height to Top of Roll Cage: 82 1/2
Tire Size: Front 18 x 9 x 12-1/8, Rear 18 x 5 x 12-1/8
EQUIPPED WITH:
Solid Cushion Type Tires
Propane Water Cooled Engine
Head Lights
Operators Seat Side Wings and Seat Belt
Tow Pocket at Rear of Truck
Removeable Roll Cage
Single Speed Transmission
Operation Hour Meter Showing 1215 Hours
Gages for Amperes, Oil Pressure and Water Temperature
Manual Engine Choke
3-Stage Mast
EQUIPPED WITH:
Equipped for Fork Side Shifter Attachment - NO Attchment
(Has Hydraulic System, Control Lever and Hose Reel for Side
Shifter Attachment)
Manual Fork Positioning
No Fire Extinguisher
Propane Tank
Overall Condition Is GOOD
Overall Size: 43-1/2 L-R x 132 F-B x 82-1/2 H
Approx. Weight: 10,750 Lb.
PRICE: F.O.B. OUR WAREHOUSE, YORK, PA
Model # CX6-753-425E Serial # 685-60-3955 Stock# 99306 Rated
Capacity: 8,000 Lb.
Capacity with Load Center 24 From Face of Fork and 21 Above Forks:
8000 Lb.
Maximum Lift Height: 147 (12' 3)
Free Lift: 14-1/2
Fork Width: 5-3/4
Fork Length: 46
Maximum Distance Across Forks: 39-1/4
Overall Height To Top of Mast: 94-1/4
Overall Height to Top of Roll Cage: 83-1/4
Tire Size: Front 21 x 9 x 15, Rear 18 x 5 x 12-1/8
EQUIPPED WITH:
Solid Cushion Type Tires
Propane Water Cooled Engine
Head Lights
Operators Seat Side Wings and Seat Belt
Tow Pocket at Rear of Truck
Removeable Roll Cage
2-Speed Transmission, Shift Lefer for High or Low Gear
Gages for Amperes, Oil Pressure and Water Temperature
Manual Engine Choke
2-Stage Mast
Manual Fork Positioning
EQUIPPED WITH:
No Fire Extinguisher
Propane Tank
Overall Condition Is GOOD
Overall Size: 46 L-R x 146 F-B x 94-1/4 H
Approx. Weight: 12,275 Lb.
PRICE: F.O.B. OUR WAREHOUSE, YORK, PA
Catalog # DTGB-0118-4S Serial # Unknown Stock# 371 Type QL
Delta-Delta
5.0% Impedance, 3 Phase, 60 Cycle
40 Deg. C Ambient, 150 Deg. C Rise, 220 C System, IS-19D
Primary: 480 Volts (Line-Line)
Secondary: 240 Volts (Line-Line)
Electrostatic Ground Shield in Each Phase
Jumper Connections:
Tap 1 502 Volts
Tap 2 493 Volts
Tap 3 480 Volts
Tap 4 467 Volts
Tap 5 458 Volts
Tap 6 444 Volts
Tap 7 431 Volts
Overall Dimensions: 31-1/2 L-R x 23 F-B x 35-1/2 H
PRICE: F.O.B. OUR WAREHOUSE, YORK, PA ………. $1,000.00
Catalog # DTGB-0118-4S Serial # Unknown Stock# 370 Type QL
Delta-Delta
5.0% Impedance, 3 Phase, 60 Cycle
40 Deg. C Ambient, 150 Deg. C Rise, 220 C System, IS-19D
Primary: 480 Volts (Line-Line)
Secondary: 240 Volts (Line-Line)
Electrostatic Ground Shield in Each Phase
Jumper Connections:
Tap 1 502 Volts
Tap 2 493 Volts
Tap 3 480 Volts
Tap 4 467 Volts
Tap 5 458 Volts
Tap 6 444 Volts
Tap 7 431 Volts
Overall Dimensions: 31-1/2 L-R x 23 F-B x 35-1/2 H
PRICE: F.O.B. OUR WAREHOUSE, YORK, PA ………. $1,000.00
Model
9T21B3122-G3, Type ML Serial # None Stock# 369 Style G
Primary Volts: 460 Delta with Full Current Taps
Secondary Volts: 460 Y/266
118 KVA, 60 Cycle, 3 Phase, Winding Rise 150 Deg. C
5.31% Impedance at 170 Deg. C
EQUIPPED WITH:
Fused Disconnect Box on Right Side, Cutler Hammer 60 Amp
Hyle-National Quick Disconnect Plug Socket on Left Side
Overall Size: 47 L-R x 27 F-B x 36 H
Weight: 700 Lb.
Condition: Excellent
PRICE: F.O.B. OUR WAREHOUSE, YORK, PA ………. $1,000.00
3,351 Horsepower DC Kocks Mill Motor
Model #EN221032
2500KW
Type: CDF1942
8 pole
700 VDC
500-1000 RPM
SF 1.00
Never installed or used. Still in wrap.
Drawing available upon request
PUSH RODS, PUMP DRIVES, rh CRANK (S) lh
CRANK(S), camshafts, connecting rod(s), pump(s_), Piston
assemblies. Various smaller parts/... ALL NEW and Preserved
condition. Engines are used in marine propulsion plants!
Diesel powered generators, 15 KW, 240/416V
400 HZ 3 Ph; 120/208V 400 HZ 3 ph; Model MEP 113A,Type I Class I
Mode II. Manufactured by Libby Welding. Powered by either White or
Hercules Diesel. Low hours. Trailer mounted or not; priced each
way.
High power in a small package. 115/230 Vac
autoranging input to 5Vdc Remote sensed Current limited output.
Has OVP and thermal shutdown. Brand new, in original shipping
boxes.
Technical
Information This coal-fired power
plant consists of four 60-cycle units ranging from 7.5 MW up to 15
MW (41.5 MW total). The station has been out of service since 1985
for Units 1 & 2, and since 1991 for Units 3 & 4. These
coal-fired units were well-maintained and are located in an
enclosed structure. They include two 7.5 MW (ACG), one 11.5 MW (ACG),
and one 15 MW (HCG) condensing steam turbines. Boilers, coal
conveyor systems, crushers, transformers, auxiliary systems,
and controls are also available.
Background
Located in the mid-western part of the United States, the customer
essentially operated these units until 1991, when rail service was
no longer available and trucking of fuel became too expensive.
Operation of Units 1 & 2 (7.5 MW each) commenced in 1949, and
they were retired in 1985. Unit 3 (12 MW) was put into service in
1951; Unit #4 (15 MW) was put into service in 1954; and both were
then retired in 1991. The units were kept on turning gear until
1998, but have been kept in a controlled environment since that
time. Two of the boilers are 90,000 lbs / hr. stoker-type units
(Units 1 & 2). Unit 3 boiler is a 125,000 lbs. / hr stoker-type
unit. And Unit 4 boiler is a 165,000 lbs. / hr. pulverized coal
type with electrostatic precipitator.
Inspection
Based on a letter of intent from a financially responsible
company, inspection of the units can be immediate. Buyers can
inspect the equipment with their own engineers, and MARCOR can
arrange for representatives of the utility to be present to answer
questions.
Equipment
Data are provided as follows:
Units No. 1 & 2 Turbines
Manufacturer
Elliott Company
Unit
No. 1 Serial Number 13546
Unit
No. 2 Serial Number 13547
Rated
capacity, kW 7500
Rotational
Speed, rpm 3600
Throttle
steam pressure, psig 600
Throttle
steam temperature, degrees, F 825
Exhaust
pressure, in. Hg abs 2.1
Number
of extraction points 3
Generators (Air Cooled)
Manufacturer
Elliott Company
Unit
No. 1 Serial Number 2075
Unit
No. 2 Serial Number 2076
Rated
capacity, kva 9375
Rated
kw @ 0.80 P.F. 7500
Volts
4160
Amperes1302
Phase
3
Cycles
60
Units No. 1 & 2: Surface Condensers
Manufacturer
Condenser Service & Engineering Co.
Manufacturer’s
order number 470352
Condensing
surface, sq. ft. 10,000
Number
of tubes 3,184
Tube
size and weight 3/4" - #18 BWG
Tube
length 16 - 0
Number
of passes 2
Steam Generating Units
Boiler
manufacturer Edge Moor Iron Works Co. Inc.
Unit
No. 1 Serial Number 3979
Unit
No. 2 Serial Number 3980
Continuous
capacity, lbs. per hour 90,000
Maximum
capacity, lbs. per hour 100,000
Superheated
steam pressure, psig 610
Superheated
steam temp., degrees F 825
Furnace
volume, cu. ft.6,340
Stoker
manufacturer Detroit Stoker Company
Order
number 37-RG-1320
Active
grate area 202
Transformers
Unit
Serial # Manufacturer Rating
MVA
Primary
Voltage
kv
Secondary
Voltage
kv
Imp. Conn.
192685
Standard 10 96 4.16 7.4 D-Y
293048
Standard 10 96 4.16 7.4 D-Y
32309315
Allis Chalmers 15 69 13.8 6.9 D-Y
4005430
Moloney 20 69 13.8 7.05 D-Y
Sta.5062839
Westinghouse
Unit
Aux. 3.75
Sta.4088323
Westinghouse Gen. Sta . 1 69 .48 7.8
D-Y
Sta.5127059
Westinghouse
C
T Supply 2.4 .48
D-D
Unit No. 3 Turbine
Manufacturer
Elliott Company
Unit
No. 3 Serial Number 14387
Rated
capacity, kw 11500
Rotational
Speed, rpm 3600
Throttle
steam pressure, psig 600
Throttle
steam temp., degrees F 825
Exhaust
pressure, in. Hg abs 2
Number
of extraction points 4
Generator (Air Cooled)
ManufacturerElliott
Company
Unit
No. 3 Serial Number 1S8208
Rated
Capacity, kva13,529
Rated
kW @ 0.80 P.F. 11,500
Volts
13,800
Amperes567
Phase3
Cycles6
Unit No. 3: Surface Condensers
Manufacturer
Condenser Service & Engineering Co.
Serial
Number 49A0282
Condensing
surface, sq. ft. 14,000
Number
of tubes 3,820
Tube
size and weight 7/8" - #18 BWG
Tube
length 16 - 2 5/8
Number
of passes 2
Steam Generating Units
Boiler
Manufacturer Riley Stoker Corp.
Unit
No. 3 Serial Number 2721
Continuous
capacity, lbs. per hr. 125,000
Maximum
capacity, lbs. per hr. 140,000
Superheated
steam pressure, psig 610
Superheated
steam temp., degrees F 825
Furnace
volume, cu. ft. 10,045
Stoker
manufacturer Riley Stoker Corp.
Order
number
Active
grate area265
Unit No. 4: Turbine
Manufacturer
Elliott Company
Unit
No. 4 Serial Number 15557
Rated
capacity, kW 15,000
Rotational
speed , rpm3,600
Throttle
steam pressure, psig 850
Throttle
steam temp., degrees F 900
Exhaust
pressure, in Hg abs. 1.5
Number
of extraction points 4
Generator (Hydrogen Cooled)
Manufacturer
Elliott Company
Unit
No. 4 Serial Number 1S8884
Rated
capacity, kva 17,647
Rated
kw @ 0.80 P.F. 15,000
Volts
13,800
Amperes738
Phase
3
Cycles
60
Unit No. 4: Surface Condensers
Manufacturer
Condenser Service & Engineering Co.
Serial
Number 511586
Condensing
surface, sq. ft. 14,000
Number
of tubes 3,820
Tube
size and weight 7/8" - #18 BWG
Tube
length 16 - 0
Number
of passes 2
Steam Generating Units
Boiler
Manufacturer Riley Stoker Corp.
Unit
No. 4 Serial Number 2896
Continuous
capacity, lbs. per hour 165,000
Maximum
capacity, lbs. per hour 165,000
Superheated
steam pressure, psig 900
Superheated
steam temp., degrees F 910
Furnace
volume, cu. ft.12,750
Type
of firing Pulverized coal and natural gas
We urgently need a 50-100 MW powerbarge for a
government in the Middle East. Our reps have established excellent
rapport on Ministery level, so anything suitable will be purchased
immediately.